Skip to main content
Free Delivery Over $499*
Discreet Shipping
3000+ Products
140K+ Orders Dispatched

Horiba LAQUA Standard Handheld Multi-Meters - PC210-K | pH/ORP/Cond/TDS/Res/Sal/Temp

PC210-K | pH / ORP / Cond / TDS / Res / Sal / Temp

SKU: MLTMTR10107
|

FREE SHIPPING

Qty:

Pick up at store Free

Delivery Charge: Free

International shipping

Click here

SECURE PAYMENTS WITH

BUY NOW, PAY LATER

Pay in 4, interest-free. Afterpay it.

ZIP NOW, PAY LATER

Repay on a convenient weekly, fortnightly or monthly schedule.

ENJOY NOW, PAY LATER

Designed for use with one hand and with an IP67 waterproof rating and shock-resistant casing, this meter can be used for long periods, even in dark places, making it ideal for field measurements in rivers and lakes.

Specifications

  • pH Range: -2.00 to 16.00 pH
  • Resolution: 0.01 pH
  • Accuracy: ± 0.01 pH
  • Calibration Points: Up to 5 (USA & NIST), Up to 6 (DIN)
  • Buffer Options: USA, NIST, DIN
  • ORP Range: ± 2000 mV
  • Resolution: 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV)
  • Accuracy: ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV)
  • Calibration Option: Yes
  • Conductivity Range: ...µS/cm to 200.0 mS/cm (k=1.0)
  • Resolution: 0.05% full scale
  • Accuracy: ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm
  • Reference Temperature: 15 to 30 °C (adjustable)
  • Temperature Coefficient: 0.00 to 10.00% (adjustable)
  • Cell Constant: 0.1, 1.0, 10.0 (adjustable)
  • Calibration Points: Up to 4 (Auto) / Up to 5 (Manual)
  • Unit Setting: S/cm, S/m (Auto-ranging)
  • TDS Range: ...ppm to 100 ppt (TDS factor=0.5)
  • Resolution: 0.01 ppm (mg/L) / 0.1 ppt (g/L)
  • Accuracy: ±0.1% full scale
  • Calibration Curves: Linear (0.40 to 1.00), EN27888, 442, NaCl
  • Resistivity Range: 0.000 Ω•cm to 20.0 MΩ•cm
  • Resolution: 0.05% full scale
  • Accuracy: ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm
  • Salinity Range: 0.0 to 100.0 ppt / 0.00 to 10.00 %
  • Resolution: 0.1 ppt / 0.01 %
  • Accuracy: ±0.2% full scale
  • Calibration Curves: NaCl, Seawater
  • Calibration Option: Yes
  • Temperature Range: -30.0 to 130.0 °C / -22.0 to 266.0 °F
  • Resolution: 0.1 °C / °F
  • Accuracy: ± 0.5 °C / ± 0.9 °F
  • Calibration Option: Yes
  • Memory Data: 500
  • Auto Log Data: Yes
  • Measurement Modes: Auto Stable, Auto Hold, Real Time
  • Offset / Average Slope Display: Yes
  • Calibration Alarm: Yes (Programmable: up to 90 days)
  • Auto Shut-Off: Yes (Programmable: up to 30 minutes)
  • Electrode Status: Yes (On screen display)
  • Diagnostic Messages: Yes
  • Software Upgrade: Yes via PC (USB) cable PN 3200779639
  • Meter Inputs: 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors)
  • Meter Output: phono (for software upgrade only)
  • Display: Custom LCD with backlight
  • Housing: IP67, shock & scratch resistant, non-slip
  • Power Requirement: 2 x AA batteries
  • Battery Life: > 500 hours
  • Meter Dimensions: 160 (L) x 80 (W) x 40.60 (H) mm
  • Meter Weight: Approx. 260g (with batteries) / 216g (without batteries)

In The Box

  • [1] x LAQUA PC210 dual channel pH/ORP/Cond/TDS/Res/Sal/Temp meter
  • [2] x AA batteries
  • [1] x Manual and quick guide
  • [1] x 9652-10D plastic-body, gel-filled pH electrode with integrated temperature sensor
  • [1] x 9383-10D plastic-body, Ti/Pt black, conductivity probe (k=1.0) with integrated temperature sensor
  • [1] x pH 4.01 and 7.00 buffers, 1413µS/cm and 12.88 mS/cm conductivity solutions (60ml each)
  • [1] x Electrode adapter
  • [1] x Carrying case
  • Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)
  • 0.01 pH resolution
  • Offset and average slope display
  • ORP calibration option
  • Automatic / manual temperature compensation and temperature calibration function
  • Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration
  • Adjustable reference temperature and temperature coefficient
  • Adjustable cell constant and selectable measurement unit
  • Conductivity and total dissolved solids (TDS) conversion
  • Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl
  • Two (2) salinity calibration curves: NaCl, Seawater 
  • Auto log data; built-in memory can store up to 500 data
  • Auto shut-off (programmable: up to 30 minutes)
  • Auto stable, auto hold, and real time measurement modes
  • Calibration alarm (programmable: up to 90 days)
  • Built-in electrode holder allows 2 electrodes to be attached 
  • Monochrome LCD with white LED backlight: 50 x 50 mm
  • Phono jack output for connecting the meter to computer for software upgrade only
  • Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip
  • Powered by 2 x AA batteries
  • Packaged with electrodes and calibration solutions in carrying case